12 zone President wired burglar alarm panel comes with 10 programmable zones and an onboard key pad.
ELECTRICAL
Quiescent current: 75ma typical with all LED’s and internal buzzer on
Maximum sounder current output: 1A
Maximum Strobe light current output: 1A
Sounder and strobe saturation Voltage: <1V at 1A
Remote keypads: five (max)
Non volatile Memory: Programming and Log
Zone response time: <500mS
Zone Loop Resistance: <5kohm for Normally Closed
POWER SUPPLY
Mains supply Voltage: 220+10% -15% 50Hz
Total current Output: 800MA at 220V AC (Fuse JA 20mm On Main Card)
Regulation: <9%
Ripple: <200mv RMS
Battery VOLTAGE: 12V DC
Battery type: SMF Rechargeable
Battery Recharge voltage: 13.8V +/-0.2V DC
Fuse: 250ma 20mm AC Mains on Power Supply Card
ENVIRONMENTAL
Operating Temperature: 0C to 45C
Storage Temperature: -20C to 60C
Maximum humidity: 95% non -condensing
Environment: residential / commercial / light industrial
PHYSICAL
Dimensions: 236 mm x 226mm x 80mm
Max Battery Dimensions: 150mm x 110mm x 64 mm